Description

The NRG 40 anemometer is designed for the acquisition of wind speed.

Case Study 2

Norway

Case Study 6

Germany

Case Study 7

Egypt

    我们如何帮助您

    请填写以下的表格,我们将尽快回复您。



    Category:

    Product Description

    The NRG 40 anemometer is designed for the acquisition of wind speed.

    NRG 40C

    The 40C bearings and low moment of inertia permit very rapid response to gusts and lulls. A four-pole magnet induces a sine wave voltage into a coil, producing an output signal with frequency proportional to wind speed.

    NRG 40H

    The 40H is based on the NRG 40 C. This Hall Effect version is engineered for electrically noisy environments and instrumentation that requires a square wave signal.

    The 40H’s Hall Effect switch produces a high-level square wave voltage signal with a frequency proportional to wind speed. This signal is easy to interface to a wide range of industrial devices including turbine controllers, programmable logic controllers (PLCs), and data loggers. A 5-26V DC excitation voltage with 5 mA of current is required.

    Both of the anemometers are constructed of rugged Lexan cups, the 40H is molded in one piece for repeatable performance. A PVC terminal boot is included with each anemometer for additional protection from the elements.

    The specifications below are from the NRG 40C

    DESCRIPTION
    Sensor type 3 Cup Anemometer
    Applications Wind resource assessment
    Meteorological studies
    Environmental monitoring
    Sensor range 1 m/s to 96 m/s
    OUTPUT SIGNAL
    Signal type Low level AC sine wave, frequency linearly proportional to wind speed
    Anemometer Transfer Function Consensus Transfer Function:
    Scale Factor (Slope): 0.765 m/s/Hz
    Offset: 0.35 m/s
    Output voltage at threshold 80 mV (peak-to-peak) minimum
    Output voltage at 60Hz 12 V (peak-to-peak) typical
    Output amplitude NOT proportional to wind speed
    Output amplitude NOT proportional to wind speed
    Output signal range 0 Hz to 125 Hz (at 96m/s, highest recorded)
    RESPONSE CHARACTERISTICS
    Distance constant (63% recovery) 2.55 m at 5m/s per ASTM D 5096-02
    2.56 m at 10m/s per ASTM D 5096-02
    Swept diameter of rotor 190 mm
    INSTALLATION
    Mounting Onto a 13 mm diameter mast with cotter pin and set screw
    Tools required 0.25 inch nut driver, petroleum jelly, electrical tape
    ENVIRONMENTAL
    Operating temperature range -55 °C to 60 °C
    Operating humidity range 0 to 100% RH
    PHYSICAL
    Connections 4-40 brass hex nut/post terminals
    Weight 0.14 kg
    Dimensions 3 cups of conical cross-section, 51 mm dia.
    81 mm overall assembly height
    MATERIALS
    Cups One piece injection-molded black polycarbonate
    Body Housing is black ABS plastic
    Shaft Beryllium copper, fully hardened
    Bearing Modified Teflon, self-lubricating
    Magnet Indox 1, 25 mm diameter, 13 mm long, 4 poles
    Coil Single coil, bobbin wound, 4100 turns of #40 wire, shielded for ESD protection
    Boot Protective PVC sensor terminal boot included
    Terminals Brass