Thies First Class Advanced X

Thies Clima First Class Anemometer X

Descripción

The Thies First Class Advanced X is the latest cup anemometer from Thies Clima and offers wind speed readings with pressure compensation by use of the internal pressure sensor. The anemometer also measures pressure, vibration, tilt and acceleration, all readings available via RS-485 in the Orbit 360 Premium data logger.

Case Study 2

Norway

Case Study 6

Germany

Case Study 7

Egypt

¿CÓMO PODEMOS AYUDARTE?

Dinos que necesitas rellenando el siguiente formulario y nos pondremos en contacto.



The cup anemometer is optimized for best possible dynamic behavior even at high turbulence intensity and has minimal over-speeding while having a very low starting value.

  • Horizontal component of the wind speed with pressure compensation
  • Horizontal component of the wind speed with no pressure compensation
  • Absolute and relative air pressure
  • Inclination angle between the X-axis and horizontal (tilt)
  • Vibration measurements (X, Y axis)

The cup anemometer is supplied with a Measnet calibration certificate and is fully compatible with the Orbit 360 Premium data logger.

For winter operation Advanced X cup anemometer (version 4.3352.00.400) is equipped with an electronically regulated heating. This heating can alternatively be controlled remotely via the Orbit 360 data logger.

The Thies First Class Advanced X is classified according to the latest IEC standard IEC61400-12-1 Ed.2.

WIND SPEED
Measuring range
0 … 75 m/s
Accuracy
< 1 % of meas. value (0.3 ... 50 m/s) or < ±0.2 m/s
Linearity
r > 0.99999 ( 4 … 20 m/s )
Inclined flow
< 0.1% ( mean deviation from cosinus line at12 m/s ; ±20 ° )
Delay distance
< 3 m ( aac. to ASTM D 5096-96 )
AIR PRESSURE
Measuring range
300 … 1100 hPa
Accuracy
±1 hPa @ 20 °C
INDICATION
Measuring range
-89.9 … +89.9 °
Accuracy
±1 °
Measuring axis
X, Y, Z
VIBRATION
Measuring range
0 … 50 Hz
Accuracy
±0.4 Hz
Measuring axis
X, Y, Z
Acceleration
Measuring range
±8 g
Accuracy
±30 mg
DATA OUTPUT DIGITAL
Interface
RS485
Baudrate
1200 … 57600 Baud
Duplex mode
Half duplex
Protocol
ASCII / MODBUS
Frequency
1082 Hz @ 50 m/s
OPERATING VOLTAGE
Electronic
3.7 … 42 V DC
40 mA typ.
100 mA max.
Heating
24 V AC/DC, max 25 W
GENERAL
Ambient temp.
-50 … +80 °C
Electr. connection
8 pol. plug connection
Mounting
onto mast tube Ø 1“
Protection
IP 55
Survival speed
80 m/s ( min. 30 minutes )
Weight
0.5 kg
Fixing boring
Ø 35 x 25 mm
Matirial housing
aluminium, anodised
Material cup star
carbon-fiber glass reinforced