Thies First Class Advanced X

Description

The Thies First Class Advanced X is the latest cup anemometer from Thies Clima and offers wind speed readings with pressure compensation by use of the internal pressure sensor. The anemometer also measures pressure, vibration, tilt and acceleration, all readings available via RS-485 in the Orbit 360 Premium data logger.

Case Study 2

Norway

Case Study 6

Germany

Case Study 7

Egypt

    我们如何帮助您

    请填写以下的表格,我们将尽快回复您。



    Product Description

    The cup anemometer is optimized for best possible dynamic behavior even at high turbulence intensity and has minimal over-speeding while having a very low starting value.

    • Horizontal component of the wind speed with pressure compensation
    • Horizontal component of the wind speed with no pressure compensation
    • Absolute and relative air pressure
    • Inclination angle between the X-axis and horizontal (tilt)
    • Vibration measurements (X, Y axis)

    The cup anemometer is supplied with a Measnet calibration certificate and is fully compatible with the Orbit 360 Premium data logger.

    For winter operation Advanced X cup anemometer (version 4.3352.00.400) is equipped with an electronically regulated heating. This heating can alternatively be controlled remotely via the Orbit 360 data logger.

    The Thies First Class Advanced X is classified according to the latest IEC standard IEC61400-12-1 Ed.2.

    WIND SPEED
    Measuring range
    0 … 75 m/s
    Accuracy
    < 1 % of meas. value (0.3 ... 50 m/s) or < ±0.2 m/s
    Linearity
    r > 0.99999 ( 4 … 20 m/s )
    Inclined flow
    < 0.1% ( mean deviation from cosinus line at12 m/s ; ±20 ° )
    Delay distance
    < 3 m ( aac. to ASTM D 5096-96 )
    AIR PRESSURE
    Measuring range
    300 … 1100 hPa
    Accuracy
    ±1 hPa @ 20 °C
    INDICATION
    Measuring range
    -89.9 … +89.9 °
    Accuracy
    ±1 °
    Measuring axis
    X, Y, Z
    VIBRATION
    Measuring range
    0 … 50 Hz
    Accuracy
    ±0.4 Hz
    Measuring axis
    X, Y, Z
    Acceleration
    Measuring range
    ±8 g
    Accuracy
    ±30 mg
    DATA OUTPUT DIGITAL
    Interface
    RS485
    Baudrate
    1200 … 57600 Baud
    Duplex mode
    Half duplex
    Protocol
    ASCII / MODBUS
    Frequency
    1082 Hz @ 50 m/s
    OPERATING VOLTAGE
    Electronic
    3.7 … 42 V DC
    40 mA typ.
    100 mA max.
    Heating
    24 V AC/DC, max 25 W
    GENERAL
    Ambient temp.
    -50 … +80 °C
    Electr. connection
    8 pol. plug connection
    Mounting
    onto mast tube Ø 1“
    Protection
    IP 55
    Survival speed
    80 m/s ( min. 30 minutes )
    Weight
    0.5 kg
    Fixing boring
    Ø 35 x 25 mm
    Matirial housing
    aluminium, anodised
    Material cup star
    carbon-fiber glass reinforced

    Enter your keyword